Samplitude/Sequoia 10 can run on 64-bit Windows under the following conditions: 

  • The installation must be performed in the compatibility mode for Windows XP/Vista.
  • On the installation DVD, right-click setup.exe.
  • Select "Troubleshoot compatibility".
  • Select "Troubleshoot program" > "The program worked in earlier versions of Windows...".
  • When asked to select a version of Windows, select "Windows XP (Service Pack 3)". 

Versions with CodeMeter

  • Check to make sure you have the latest 64-bit CodeMeter driver installed. 

Download CodeMeter driver

  • Go to "Control Panel" > "Programs and Features" and uninstall "CodeMeter Runtime Kit 32-bit".

Installing Samplitude/Sequoia on 64-bit operating systems

To use Samplitude/Sequoia on a 64-bit operating system, you need to download and install CodeMeterRuntime64.exe from the MAGIX download area or from www.codemeter.com.

  • Go to "Start" > "All Programs" > "Accessories" > "Run" and type in "regedit".
  • Open the following key: 
    HKEY_LOCAL_MACHINE\SOFTWARE\WIBU-SYSTEMS\CodeMeter\Server
  • Right-click "Server" in the registry tree and select "Export".
  • Save the key and open it in a text editor such as Notepad.
  • Find the string HKEY_LOCAL_MACHINE\SOFTWARE\WIBU-SYSTEMS\CodeMeter\Server
    and replace it with HKEY_LOCAL_MACHINE\SOFTWARE\Wow6432Node\WIBUSYSTEMS\CodeMeter\Server
  • Save the file.
  • Double-click the file you just saved to apply the modified key to the Windows Registry.